Check the U-tube gauge on the pipe: unequal liquid levels mean the fan is pulling; level liquid means it is not. Then remember the gauge only proves airflow. A retest every two years proves the air itself, which is the point.
More detail
The manometer is wonderfully dumb: two columns of colored fluid displaced by the pressure difference the fan maintains. Memorize or mark what yours reads on a normal day, because change is the signal in both directions. A collapse toward level means the fan has quit or the pipe has blocked, ice at the discharge being the classic February cause here. A strong jump in reading can mean the pipe is choked somewhere and the fan is straining against it. Either way, listen at the fan, look at the outlet, and call if the cause is not obvious. Twice a year, add a thirty-second tour: sump cover still sealed, no new slab cracks gaping behind the storage shelves, labels still legible, fan not newly noisy. And keep the retest rhythm, every two years and after any renovation, because a gauge cannot smell radon any better than you can. A working fan over a slab with a newly opened pathway can still lose ground; only the number closes the loop. See what to do if levels return.